Eaton G4 PDU 42 prises EVMA8365X

Economisez $2,047.45
EatonSKU: EVMA8365X

Prix:
Prix réduit$3,371.99 Prix normal$5,419.44
Stock:
Rupture de stock

Description

Three-Phase Managed PDU Ideal for Data Center Managers with Large-Scale Distributed IT

The EVMA8365X G4 Rack PDU is ideal for streamlining PDU procurement and deployment within a 42U rack in an enterprise data center, colocation data center or distributed IT infrastructure. Equipped to meet even the most diverse data center rack power needs, the EVMA8365X delivers versatile, enterprise-quality power distribution.

Market-Leading Cybersecurity Ensures Your Data Is Kept Safe

Chain-of-trust encryption and secure firmware boot capability prevent the EVMA8365X PDU from being a cyberattack vulnerability point on a network. An embedded, hot-swappable gigabit network module (GNM) offers enhanced management and cybersecurity, including zero-trust architecture and zero-touch provisioning. The EVMA8365X is compatible with select Eaton Brightlayer Data Centers suite software solutions that enable extensive automation and remote management to shorten response times to power issues and ensure timely updates for stronger cybersecurity.

Remote Management Saves Time and Money

The GNM with multi-color screen supports performance management software for real-time reports, trend charts, dashboards and alerts that are prioritized by severity, as well as remote troubleshooting and automated responses during power events. The EVMA8365X is compatible with optional environmental sensors (sold separately) that provide alerts about temperature, humidity and dry-contact device connections.

42 Outlets Give You Plenty of Power Options

The EVMA8365X features 24 C13 outlets, which accept C14 connectors, and 18 high-retention C39 combo outlets, which accept both C14 and C20 connectors, adding flexibility to deployments and reducing the quantity of PDUs you will need to purchase and install.

Outlet-Level Control Boosts Performance and Efficiency

All 42 outlets provide metering, monitoring and switching for granular power data and precision control of power delivery. The outlets are evenly distributed into six color-coded load banks, each with its own circuit breaker, to improve load balancing and organize connections in a crowded rack. You can get more uptime by disabling a load bank before its connected equipment overloads the system, rather than disabling the entire PDU and shutting down all equipment.

Convenient Box-to-Rack Installation

This EVMA8365X PDU features toolless mounting buttons that allow front- or side-facing rack installation, depending on your rack's layout and your power needs. The 10-foot power cord with CS8365 input connects to a compatible AC source. Low-profile circuit breakers are flush with the lightweight aluminum chassis, and the narrow two-inch width saves space within the rack for revenue-generating equipment. You can cascade up to 40 EVMA8365X models with each model maintaining its own individual IP address from a single network connection point.

. .
  • Limited Warranty : 3 Year
  • Receptacle Type : IEC 60309 C13,IEC 60320 C39
  • Receptacle Detail : 24 x IEC 60320 C13,18 x IEC 60320 C39
  • Phase : Three Phase
  • PDU Type : Managed
  • Power Rating (Watt) : 14.40 kW
  • Input Voltage : 230 V AC
  • Product Series : G4
  • Minimum Operating Temperature : 32°F (0°C)
  • Form Factor : Rack
  • Manufacturer Website Address : http://www.eaton.com/EatonCom/Markets/NorthAmerica
  • Network (RJ-45) : Yes
  • Plug/Connector Type : CS8365
  • Cord Length : 10 ft
  • Product Type : PDU
  • Length : 2.05" (52.07 mm)
  • Manufacturer : Eaton Corporation
  • Maximum Operating Temperature : 140°F (60°C)
  • Mounting Orientation : Vertical
  • Input Current : 50 A
  • Rack Height : 0U